Kia Sedona: Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Components and Components Location - Automatic Transaxle Control System - Automatic Transaxle System - Kia Sedona YP Service ManualKia Sedona: Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Components and Components Location

Third generation YP (2014-2026) / Kia Sedona YP Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Components and Components Location

Component Location

1. Overdrive clutch control solenoid valve (OD/C_VFS)
Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Specifications
Specification Item SpecificationControl typeN/H (Normal High)Control pressure kpa (kgf/cm², psi)"500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42)"Current value (mA)50 ~ 850Coil resistance(Ω)5.1 ± 0.3 ...

Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Description and Operation
Description • Overdrive clutch control solenoid valve is a Variable Force Solenoid (VFS) type. • When TCM supplies variable current to solenoid valve, hydraulic pressure of und ...

Other Information:

Repair procedures
Replacement 1. Remove the cap (A), the nuts and the wiper arm (B). Tightening torque : 22.6 ~ 26.5 N.m(2.3 ~ 2.7 kgf.m, 16.6 ~ 19.5 lb-ft) 2. Disconnect the cowl top cover nozzle hose (A ...

Line Pressure Control Solenoid Vale Components and Components Location
Component Location 1. Line pressure control solenoid valve (LINE_VFS) ...