Kia Sedona: Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Description and Operation - Automatic Transaxle Control System - Automatic Transaxle System - Kia Sedona YP Service ManualKia Sedona: Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Description and Operation

Third generation YP (2014-2026) / Kia Sedona YP Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Description and Operation

Description
Overdrive clutch control solenoid valve is a Variable Force Solenoid (VFS) type.
When TCM supplies variable current to solenoid valve, hydraulic pressure of underdrive brake is controlled by solenoid valve.

Overdrive clutch control solenoid valve operation table
 
OD/C_VFS
N/H
N, P
 
1
Δ
2

3

4
 
5
 
6
 
R
 

● : Connected status
Δ : Connected at vehicle speed above 8km/h
Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Components and Components Location
Component Location 1. Overdrive clutch control solenoid valve (OD/C_VFS) ...

Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Schematic Diagrams
Circuit Diagram ...