Description
Overdrive clutch control solenoid valve is a Variable Force Solenoid (VFS) type.
When TCM supplies variable current to solenoid valve, hydraulic pressure of underdrive brake is controlled by solenoid valve.

Overdrive clutch control solenoid valve operation table
 
OD/C_VFS
N/H
N, P
 
1
Δ
2

3

4
 
5
 
6
 
R
 

● : Connected status
Δ : Connected at vehicle speed above 8km/h
Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Components and Components Location
Component Location 1. Overdrive clutch control solenoid valve (OD/C_VFS) ...

Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Schematic Diagrams
Circuit Diagram ...

Other Information:

Tires and wheels
Tire care For proper maintenance, safety, and maximum fuel economy, you must always maintain recommended tire inflation pressures and stay within the load limits and weight distribution recommend ...

Evaporator Temperature Sensor Repair procedures
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the evaporator temperature sensor connector. 3. Measure resistance between terminals “+” and “-” of the evaporator tempera ...