The A/C Pressure Transducer (APT) converts the pressure value
of high pressure line into voltage value after measuring it. By
converted voltage value, engine ECU controls the cooling fan by
operating it at high speed or low speed. Engine ECU stops the operation
of the compressor when the temperature of refrigerant line is very high
or very low irregularly to optimize air conditioning system.
Replacement
1.
Remove the condenser.
2.
Remove the cap (B) on the bottom of the condenser with an L wrench (A).
Tightening torque :
9.8 ~ 14.7 N.m (1.0 ~ 1.5 kgf.m, 7.2 ~ 10.8 lb-ft)
...
Inspection
1.
Measure the pressure of high pressure line by measuring voltage output between terminals “1” and “2”.
2.
Inspect the voltage value to determine whether it is within speci ...
Other Information:
Rear Seat Assembly Components and Components Location
Component Location
[Second Row Seat Assembly]
1. Second Row Seat Assembly [RH]2. Second Row Center Seat Assembly3. Second Row Seat Assembly [LH]
1. Second Row Seat Assembly
[Third ...
Cooling Fan Repair procedures
Removal and Installation
1.
Disconnect the battery negative terminal.
2.
Remove the air duct (A).
3.
Remove the front bumper cover.
(Refer to Body - "Front Bumper Cover")
4.
Disconnec ...