The A/C Pressure Transducer (APT) converts the pressure value
of high pressure line into voltage value after measuring it. By
converted voltage value, engine ECU controls the cooling fan by
operating it at high speed or low speed. Engine ECU stops the operation
of the compressor when the temperature of refrigerant line is very high
or very low irregularly to optimize air conditioning system.
Replacement
1.
Remove the condenser.
2.
Remove the cap (B) on the bottom of the condenser with an L wrench (A).
Tightening torque :
9.8 ~ 14.7 N.m (1.0 ~ 1.5 kgf.m, 7.2 ~ 10.8 lb-ft)
...
Inspection
1.
Measure the pressure of high pressure line by measuring voltage output between terminals “1” and “2”.
2.
Inspect the voltage value to determine whether it is within speci ...
Other Information:
Towing service
If emergency towing is necessary, we recommend having it done by an authorized
Kia dealer or a commercial tow-truck service. Proper lifting and towing procedures
are necessary to prevent damage ...
In-car Sensor (DATC only) Description and Operation
Description
The In-car air temperature sensor is built in the heater & A/C control unit.
The sensor consists of a thermistor that measures the inside