Inspection |
[Resistance Inspection] |
1. |
Turn the ignition switch OFF. |
2. |
Remove the OTS. (Refer to "Removal") |
3. |
After immersing the thermistor of the sensor into engine coolant, measure resistance between the OTS terminals 1 and 2. |
4. |
Check that the resistance is within the specification.
|
[Voltage Inspection] |
1. |
Connect the GDS to DLC. |
2. |
Turn the ignition ON or idle. |
3. |
Check the OTS temperatuere in the GDS service data. |
4. |
Check that the resistance is within the specification.
|
Removal |
1. |
Turn the ignition switch OFF and disconnect the battery negative (-) cable. |
2. |
Remove the air cleaner assembly.
(Refer to Engine Mechanical System - "Air Cleaner") |
3. |
Disconnect the connector (A), and then remove the CVVT oil temperature sensor (B). |
Installation |
|
1. |
Install in the reverse order of removal.
|
Condenser Repair procedures
Inspection
1.
Check the condenser fins for clogging and damage. If clogged,
clean them with water, and blow them with compressed air. If bent,
gently bend them using a screwdriver or pliers.
...
Assist Handle Components and Components Location
Component Location
1. Assist handle
...