Problem Symptoms Table
Before replacing or repairing air conditioning components, first determine if the malfunction is due to lack of refrigerant, air flow or compressor.
Use the following table to find the cause of the problem. The numbers indicate the order of the likely cause of the problem. Check each part in order. If necessary, replace the corresponding parts.
After fixing the area of malfunction, check the complete system to ensure satisfactory performance.
Standard:
Symptom
Suspected Area
No blower operation
1. Blower fuse
2. Blower relay
3. Blower motor
4. Power mosfet
5. Blower speed control switch
6. Wire harness
No air temperature control
1. Engine coolant capacity
2. Heater control assembly
No compressor operation
1. Refrigerant capacity
2. A/C fuse
3. Clutch limiter
4. Compressor
5. A/C pressure transducer
6. A/C switch
7. Evaporator temperature sensor
8. Wire harness
Vented air not cold
1. Refrigerant capacity
2. Refrigerant pressure
3. Drive belt
4. Clutch limiter
5. Compressor
6. A/C pressure transducer
7. Evaporator temperature sensor
8. A/C switch
9. Heater control assembly
10. Wire harness
Insufficient cooling
1. Refrigerant capacity
2. Drive belt
3. Clutch limiter
4. Compressor
5. Condenser
6. Expansion valve
7. Evaporator
8. Refrigerant lines
9. A/C pressure transducer
10. Heater control assembly
No engine idle-up when A/C switch ON
1. Engine ECM
2. Wire harness
No air inlet control
1. Heater control assembly
No mode control
1. Heater control assembly
2. Mode actuator
No cooling fan operation
1. Cooling fan fuse
2. Fan motor
3. Engine ECM
4. Wire harness

Special Service Tools
Special Service Tools Tool (Number and name)IllustrationUse09977-3R000Disc & hub assembly bolt removerRemoval and installation of disc & hub assembly. ...

Air conditioning System
...

Other Information:

Evaporator Temperature Sensor Description and Operation
Description The evaporator temperature sensor detects the evaporator core temperature and interrupt compressor relay power in order to prevent evaporator from freezing by excessive cooling. ...

Torque Converter Control Solenoid Valve (T/CON_VFS) Repair procedures
Inspection 1. Turn ignition switch OFF. 2. Remove the battery and battery tray. (Refer to Engine Electrical System - "Battery") 3. Disconnect the solenoid valve connector (A). 4. Me ...