Kia Sedona: Alternator Repair procedures - Charging System - Engine Electrical System - Kia Sedona YP Service ManualKia Sedona: Alternator Repair procedures

Third generation YP (2014-2024) / Kia Sedona YP Service Manual / Engine Electrical System / Charging System / Alternator Repair procedures

Removal
1.
Disconnect the battery negative (-) terminal.
2.
Remove the cooling fan.
(Refer to Engine Mechanical System - "Cooling Fan")
3.
Lift the vehicle.
4.
Remove the engine room RH side cover.
(Refer to Engine Mechanical System - Engine Room Under Cover - Repair procedures - "Engine Room Side Cover")
5.
To release the auto tension pully (A), turn the drive belt tensioner counterclockwise.

6.
Remove the drive belt (A).

7.
Disconnect the alternator connector (A).

8.
Disconnect the alternator cable (A) from the ''B'' terminal.

Alternator "B" terminal mounting nut:
9.8 ~ 11.8 Nm (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 Ib-ft)

9.
Remove the alternator (B) after loosening the mounting bolts (A).

Alternator mounting bolt:
49.0 ~ 63.7 Nm (5.0 ~ 6.5 kgf.m, 36.2 ~ 47.0 Ib-ft)

Installation
1.
Install in the reverse order of removal.
2.
Install the drive belt.
(Refer to Engine Mechanical System - "Drive Belt")
Alternator Schematic Diagrams
Circuit Diagram     • COM signal - When controlling the voltage generated, the ECM sends the target voltage data to the alternator via a PWM signal (High volta ...

Battery Specifications
Specification ItemSpecificationModel typeCMF80L-BCICapacity [20HR/5HR] (AH)80/64 Cold Cranking Amperage (A)660 (SAE) / 528 (EN)Reserve Capacity (Min)145     • ...

Other Information:

CVVT Oil Temperature Sensor (OTS) Specifications
Specification TemperatureResistance (kΩ)Output Voltage (V) [Ref=5V]°C°F-40-4052.154.82-20-416.524.38 ~ 4.530326.03.7520682.452.60 ~ 2.91401041.111.78601400.541.06801760.290.58 ~ 0.691002120.1 ...

Passenger Airbag (PAB) Module Description and Operation
Description Passenger Airbag (PAB) module is located in the passenger crash pad. The PAB contains 2 firing squibs of airbag and 1 firing squib of active vent. The deployment timing of both 2 fi ...