Specification |
Item | Specification |
Control type | N/H (Normal High) |
Control pressure kpa (kgf/cm², psi) | 500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42) |
Current value (mA) | 50 ~ 850 |
Coil resistance(Ω) | 5.1 ± 0.3 |
Delivery Pipe Repair procedures
Removal
When removing the high pressure fuel pump, high pressure fuel
pipe, delivery pipe, and injector, injury may be caused by leakage of
high pressure fuel. For ...
Camshaft Position Sensor (CMPS) Repair procedures
Inspection
1.
Check the signal waveform of the CMPS and CKPS using the GDS.
Specification: Refer to “Wave Form”
Removal
•
DO NOT remove the cam ...