Description
Overdrive clutch control solenoid valve is a Variable Force Solenoid (VFS) type.
When TCM supplies variable current to solenoid valve, hydraulic pressure of underdrive brake is controlled by solenoid valve.

Overdrive clutch control solenoid valve operation table
 
OD/C_VFS
N/H
N, P
 
1
Δ
2

3

4
 
5
 
6
 
R
 

● : Connected status
Δ : Connected at vehicle speed above 8km/h
Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Components and Components Location
Component Location 1. Overdrive clutch control solenoid valve (OD/C_VFS) ...

Overdrive Clutch Control Solenoid Valve(OD/C_VFS) Schematic Diagrams
Circuit Diagram ...

Other Information:

AC Inverter Unit Repair procedures
Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the rear console assembly. (Refer to Body - "Floor Console Assembly") 3. Disconnect the AC inverter unit connector (A). ...

Clean air
When the ignition switch is in the ON position, the clean air function turns on automatically. Also, the clean air function turns off automatically, when the ignition switch turns to the OFF po ...