Specification |
Item | Specification |
Control type | N/H (Normal High) |
Control pressure kpa (kgf/cm², psi) | "500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42)" |
Current value (mA) | 50 ~ 850 |
Coil resistance(Ω) | 5.1 ± 0.3 |
Inside lamp
Type A
Type B
1. Open the tailgate.
2. Remove the service cover.
3. Remove the socket from the assembly by turning the socket counterclockwise
until the tabs on the socket align with the s ...
Transaxle Oil Temperature Sensor Description and Operation
Description
•
The sensor used is a thermistor (NTC) in which resistance changes with temperature variation.
•
The TCM supplies about 5 voltage to the sensor; the output value ...